Tunnel chiller 60P 70P 80P 90P can accept non-standard customization
Tunnel chiller 60P 70P 80P 90P can accept non-standard customization
Tunnel chiller 60P 70P 80P 90P can accept non-standard customization
Tunnel chiller 60P 70P 80P 90P can accept non-standard customization
Tunnel chiller 60P 70P 80P 90P can accept non-standard customization
Tunnel chiller 60P 70P 80P 90P can accept non-standard customization

Tunnel chiller 60P 70P 80P 90P can accept non-standard customization

$6,533.10/Stand
Place of Origin
China
Shipping
Air Freight, Ocean Freight, Land Freight

Product Description

Overview

brand
BD
power
30KW
specifications
Customizable for large, medium, and small sizes
type
Industrial machinery
purpose
Cooling and cooling
Air volume
filler
material quality
304 stainless steel insulated water tank
weight
600kg
type
Tower height
model
BD6666
Excess water volume
Refrigeration capacity
2KW~800KW
application area
tunnel
Processing customization
yes
Applicable scope
Mine extraction reaction kettle
Noise level
Area occupied
temperature range
Freezing method
Wind cold water cooling
Ventilation method
Flow pressure
Overall dimensions
1100 * 1000 * 1100cm
Contact mode of hot water and air
Direction of hot water and air flow
water pump
Flow rate: 15m ³/ Starting from h, lift: 49m

Product Details

Tunnel chiller 60P 70P 80P 90P can accept non-standard customization

The selection process of the chiller is as follows:
Generally, customers only know their required cold water temperature and required chilled water flow rate. According to national standards, the calculation method is as follows:
Q=CM △ T
Among them, Q is the cooling capacity we need, and the cooling capacity calculated by this formula is in KJ/h, which needs to be converted into KW
C is the specific heat capacity of the medium, which is a constant. Taking water as an example, the specific heat capacity of water is 4.2KJ/(KG. ℃)
M is the mass flow rate of the refrigerant carrier
△ T is the temperature difference between the ice water we need. For example, if we need the ice water temperature to be 7 ℃, 7 ℃ before entering the machine for use, and 12 ℃ when exiting the equipment, then △ T=12-7=5 ℃. Generally, the heat exchange temperature difference for equipment is around 5 ℃.
For example, a certain device requires an ice water temperature of 7 ℃ and a flow rate of 30m ³/ h. The refrigerant is water
So we use the formula: Q=CM △ T
Among them: C=4.2KJ/(KG. ℃)
M=10 * 1000=30000kg/h
△ T=5 ℃
Q=4.2 * 30000 * 5=630000KJ/H converted to KW is 630000/3600=175KW
Choosing a 50 horsepower screw chiller from our company Bond Refrigeration can meet the cooling capacity requirements.


Tunnel chiller 60P 70P 80P 90P can accept non-standard customization
Tunnel chiller 60P 70P 80P 90P can accept non-standard customization
Tunnel chiller 60P 70P 80P 90P can accept non-standard customization
Tunnel chiller 60P 70P 80P 90P can accept non-standard customization

Trading Area

Global

Quotation

Name
Company
Phone
Email Address
Requirements
Quotation
Guangdong, China
Chat
TradersManufacturer
Messages