Xiangke DRH-II-300 Thermal Insulation Material Fully Automatic Double Plate Thermal Conductivity Tester Protective Hot Plate Method
Xiangke DRH-II-300 Thermal Insulation Material Fully Automatic Double Plate Thermal Conductivity Tester Protective Hot Plate Method
Xiangke DRH-II-300 Thermal Insulation Material Fully Automatic Double Plate Thermal Conductivity Tester Protective Hot Plate Method
Xiangke DRH-II-300 Thermal Insulation Material Fully Automatic Double Plate Thermal Conductivity Tester Protective Hot Plate Method
Xiangke DRH-II-300 Thermal Insulation Material Fully Automatic Double Plate Thermal Conductivity Tester Protective Hot Plate Method
Xiangke DRH-II-300 Thermal Insulation Material Fully Automatic Double Plate Thermal Conductivity Tester Protective Hot Plate Method

Xiangke DRH-II-300 Thermal Insulation Material Fully Automatic Double Plate Thermal Conductivity Tester Protective Hot Plate Method

$9,581.88 - 9,872.24
Place of Origin
Xiangtan, Hunan, China
Shipping
Ocean Freight, Land Freight

Product Description

Overview

brand
Xiang family
weight
300KG
type
Double flat plate
purpose
Testing the thermal conductivity of low thermal insulation materials
accuracy
Better than 3%
size
2000 * 700 * 1400mm
variety
source
220V, 50HZ, 2KW
type
Number of boxes packed
Accuracy
resolving power
0.0001w/m * k
Graduation value
Precision
accuracy
Resolution
Processing customization
no
UV power
Probe type
Flat panel type
Applicable scope
working voltage
Imported or not
no
Indication error
Applicable industries
UV wavelength
measuring range
Operation mode
Connect computer automatic control and data processing
Display method
Measurement object
Test scope
0.0010~3.000W/mk
Measurement time
working temperature
ambient temperature
Analysis time
Testing items
Measurement repeatability
Better than 1%
Filter specifications
Continuous working hours
Temperature compensation range
Sampling flow range
encapsulation
Wooden box packaging
Batch number
two hundred and two thousand two hundred and three

Product Details

 Xiangke DRH-II-300 Thermal Insulation Material Fully Automatic Double Plate Thermal Conductivity Tester Protective Hot Plate Method

Xiangke DRH-II-300 Thermal Insulation Material Fully Automatic Double Plate Thermal Conductivity Tester Protective Hot Plate Method

Xiangke DRH-II-300 Thermal Insulation Material Fully Automatic Double Plate Thermal Conductivity Tester Protective Hot Plate Method

Xiangke DRH-II-300 Thermal Insulation Material Fully Automatic Double Plate Thermal Conductivity Tester Protective Hot Plate Method

Xiangke DRH-II-300 Thermal Insulation Material Fully Automatic Double Plate Thermal Conductivity Tester Protective Hot Plate Method

Xiangke DRH-II-300 Thermal Insulation Material Fully Automatic Double Plate Thermal Conductivity Tester Protective Hot Plate Method


Xiangke DRH-II-300 fully automatic thermal conductivity tester (dual protection hot plate method)

This instrument is based on the principle of unidirectional stable thermal conductivity. When the upper and lower surfaces of the sample are at different stable temperatures, the heat flow through the effective heat transfer area of the sample, as well as the temperature difference and thickness between the two surfaces of the sample, are measured to calculate the thermal conductivity. It meets the high-precision testing requirements of the material testing and research department for the thermal conductivity of materials. It mainly tests plastic, glass, fiber, foam, thermal insulation materials, etc. Widely used in material analysis and testing in universities, research institutions, quality inspection departments, and production factories.

Instrument reference standards:

GB/10294-2008 (Measurement of steady-state thermal resistance and related characteristics of insulation materials - Protective hot plate method);

GB/T3399-1982 (Test Method for Thermal Conductivity of Plastics, Hot Plate Method);

GB/T3139-2005 (Test Method for Thermal Conductivity of Fiber Reinforced Plastics) (Test Method for Thermal Conductivity of Fiberglass Reinforced Plastics).

GB/T10801.1-2002 (Polystyrene foam for thermal insulation) requirements for measuring thermal conductivity of polyurethane rigid foam materials;

GB/T10801.2-2002 (Extruded Polystyrene Foam for Thermal Insulation (XPS)) requirements for thermal conductivity measurement of extruded polystyrene foam;

GB/T3139-2005 (Test Method for Thermal Conductivity of Fiber Reinforced Plastics);

Requirements for thermal conductivity measurement in GB/T 17794-2008 (flexible foam rubber plastic thermal insulation products).

Performance characteristics:

1. Automatic thickness measurement: high-precision displacement sensor is used for measurement, and computer is connected for automatic thickness measurement to reduce human error.

2. Automatic pressurization system: Computer automatic pressurization, which can test the thermal conductivity under different pressures, is more scientific, data-driven, and reproducible than manual pressurization.

3. Adopting dual flat plate detection for higher accuracy.

The main technical specifications of Xiangke DRH-II-300 fully automatic thermal conductivity tester (dual protection hot plate method) are as follows:

1. Thermal conductivity range: 0.0010~3.000W/mk, displaying four decimal places;

2. Test accuracy: ± 3%;

3. Sample size: double specimen 300 × three hundred × (10-50) mm; Flatness:<0.05 mm

4. Hot surface temperature range: room temperature~100 ℃, temperature resolution 0.01 ℃, measurement accuracy 0.05 ℃;

5. Cold noodle temperature range: 0-60 ℃, temperature resolution 0.01 ℃;

6. Computer controlled fully automatic testing, data processing, and generation of inspection reports that can be printed out;

7. Adopting high-precision displacement sensors and connected to computers for automatic thickness measurement, with a measurement range of 0-50mm and a resolution of 0.01mm;

8. It can automatically pressurize and detect the thermal conductivity under different pressure states. The pressurization range is adjustable from 0 to 1000N, with a resolution of 0.1N.

9. Temperature difference between hot and cold plates: default value of 20 ℃, user can also set it by themselves

Common standard temperature difference: 20 ℃ Common temperature difference range: 15-25 ℃

Configuration: Including one DRH-II-300 fully automatic testing host, one set of software, one high-precision constant temperature water tank, and one Lenovo desktop computer (configured according to the contract).

 

Xiangke DRH-II-300 Thermal Insulation Material Fully Automatic Double Plate Thermal Conductivity Tester Protective Hot Plate Method



Xiangke DRH-II-300 Thermal Insulation Material Fully Automatic Double Plate Thermal Conductivity Tester Protective Hot Plate Method



Xiangke DRH-II-300 Thermal Insulation Material Fully Automatic Double Plate Thermal Conductivity Tester Protective Hot Plate Method
Xiangke DRH-II-300 Thermal Insulation Material Fully Automatic Double Plate Thermal Conductivity Tester Protective Hot Plate Method
Xiangke DRH-II-300 Thermal Insulation Material Fully Automatic Double Plate Thermal Conductivity Tester Protective Hot Plate Method

Trading Area

Global

Quotation

Name
Company
Phone
Email Address
Requirements
Quotation
Hunan, China