DRPL-II Metal Sheet Graphite Rubber Thermal Conductivity Tester Thermal Conductivity Tester
DRPL-II Metal Sheet Graphite Rubber Thermal Conductivity Tester Thermal Conductivity Tester
DRPL-II Metal Sheet Graphite Rubber Thermal Conductivity Tester Thermal Conductivity Tester
DRPL-II Metal Sheet Graphite Rubber Thermal Conductivity Tester Thermal Conductivity Tester
DRPL-II Metal Sheet Graphite Rubber Thermal Conductivity Tester Thermal Conductivity Tester

DRPL-II Metal Sheet Graphite Rubber Thermal Conductivity Tester Thermal Conductivity Tester

$7,259.00/Stand
Place of Origin
China
Shipping
Air Freight, Ocean Freight, Land Freight

Product Description

Overview

brand
-
Processing customization
yes
Imported or not
no
type
Thermal conductivity tester
working voltage
Please refer to the introduction for details
Precision
Please refer to the introduction for details
measuring range
0.001-5W/mk
Number of boxes packed
one
measurement accuracy
Better than 5%
producing area
China
Order number
two thousand and twenty-one
Article number
two thousand and twenty-one
model
DRPL-II
Measurable sample status
Please refer to the introduction for details
Applicable scope
Plastic, rubber, graphite, insulation materials, etc
quantity
one

Product Details

Product quotations are generally reference prices, with specific parameters, actual prices, and quantities. Please consult customer service for details. Whether it includes related matters such as tickets, the specific information shall be based on the written quotation or telephone quotation communicated. You can sign an order contract and issue a 13% value-added tax special invoice. For specific matters, please contact sales personnel: Mr. Huang 189-2461-8321DRPL-II Metal Sheet Graphite Rubber Thermal Conductivity Tester Thermal Conductivity Tester



DRPL-II Metal Sheet Graphite Rubber Thermal Conductivity Tester Thermal Conductivity Tester

1、 Overview

This instrument adopts the internationally popular method of measuring thermal conductivity using a heat flow meter, and is equipped with a computer to achieve fully automatic detection. It is redesigned based on our company's original DRPL-1 and is suitable for testing the thermal conductivity of various common materials.


This instrument is based on the principle of steady-state flat plate testing. A stable hot surface temperature is added to the hot surface, and heat is transferred to the cold surface through the sample. The heat flow transmitted is measured, and the thermal conductivity and thermal resistance can be calculated based on the thickness and heat transfer area of the sample. This testing method is simple, fast, and has good repeatability. Very suitable for research and development in material heat transfer. It can be used for testing plastics, rubber, graphite, insulation materials, etc., and is widely used in colleges, research institutes, quality inspection, factories and mines.


Reference standard for this instrument:ASTM E1530-06 Test Standard for Evaluating the Heat Transfer Resistance of Materials Using a Protected Heat Flow Meter Technique, GB/T29313-2012 Test Method for Thermal Conductivity of Electrical Insulation MaterialsASTM C518-04 Test Method for Measuring Steady Heat flux and Heat Transfer Characteristics by Heat Flow Meter; GB10295-2008 Determination of steady-state thermal resistance and related characteristics of insulation materials (heat flux meter method).


2、 Main technical parameters

 

Serial number

main parameter

DRPL-2

DRPL-2A

DRPL-2B

DRPL-2C

one

Thermal conductivity range

Plate sample 0.001-5W/mk; Cylindrical sample 3-500W/mk

5-1000W/mk

two

Testing accuracy

Better than 5%

Better than 4%

Better than 4%

Better than 5%

three

Hot plate temperature control

Room temperature -99.99 ℃

Room temperature -150.00 ℃

Or room temperature -300.00 ℃

Room temperature -150.00 ℃

Or room temperature -300.00 ℃

Room temperature -150.00 ℃

Or room temperature -300.00 ℃

four

Cold surface temperature

Forced air cooling

Forced air cooling

Thermostatic bath 5-90 ℃

(Optional according to temperature)

Thermostatic bath 5-90 ℃

(Optional according to temperature)

five

Test surface size

150 * 150mm

φ 60 (or φ 80) mm

φ 60 (or φ 80) mm

Clamping sample width 60mm

six

Experimental time

About 3 hours

About 3 hours

About 1.5 hours

About 1.5 hours

seven

Heat protection device

nothing

have

have

have

eight

Heat flow range

0.5-2000W/mtwo, braiding rate 0.25 W/mtwo.

nine

Measurement and control system

Computer automatic testing

ten

source

220V; 50Hz; Power less than 1KW (excluding constant temperature bath)

eleven

Heat flux meter

Using a WPY heat flow meter, the heat flow parameter is 23.26w/m2 * mV.

twelve

other

The use of an organic glass windshield allows for direct observation of the experimental process.

thirteen

allocation

Including one DRPL-2 testing host, one set of software, one plexiglass windshield, and the demander's own computer and printer.

Including one DRPL-2A testing host, one set of software, one plexiglass windshield, and the demander's own computer and printer.

Including one DRPL-2B testing host, one set of software, one plexiglass windshield, one high-precision constant temperature water tank, and the demander's own computer and printer.

Including one DRPL-2C testing host, one set of software, one organic glass windshield, one high-precision constant temperature water tank, one set of sample fixture, and the demander's own computer and printer.


Note: The DRPL-2C model instrument is designed for measuring high thermal conductivity thin plate samples (metal sheets, graphite sheets, etc.).




Trading Area

Global

Quotation

Name
Company
Phone
Email Address
Requirements
Quotation
Messages