Pipeline split impeller flowmeter, Jiangsu flowmeter manufacturer, domestic flowmeter brand
Pipeline split impeller flowmeter, Jiangsu flowmeter manufacturer, domestic flowmeter brand
Pipeline split impeller flowmeter, Jiangsu flowmeter manufacturer, domestic flowmeter brand
Pipeline split impeller flowmeter, Jiangsu flowmeter manufacturer, domestic flowmeter brand
Pipeline split impeller flowmeter, Jiangsu flowmeter manufacturer, domestic flowmeter brand
Pipeline split impeller flowmeter, Jiangsu flowmeter manufacturer, domestic flowmeter brand

Pipeline split impeller flowmeter, Jiangsu flowmeter manufacturer, domestic flowmeter brand

$406.50 - 435.54
Place of Origin
Shenzhen, Guangdong, China
Shipping
Ocean Freight, Air Freight

Product Description

Overview

Product characteristics
Wide range
Imported or not
no
producing area
Shenzhen
Processing customization
yes
brand
VOLKE
model
FIC impeller flow sensor
type
Impeller flowmeter
measuring range
0.1-6m/sm3/h
Accuracy level
± 1%
Nominal diameter
DN15 to DN600mm
Applicable medium
Liquid/Fluid
working pressure
1MPaMPa
working temperature
0-80 ℃

Product Details

Pipeline split impeller flowmeter, Jiangsu flowmeter manufacturer, domestic flowmeter brand
Pipeline split impeller flowmeter, Jiangsu flowmeter manufacturer, domestic flowmeter brand
Pipeline split impeller flowmeter, Jiangsu flowmeter manufacturer, domestic flowmeter brand

1. Fully digital circuit design with high measurement and control accuracy

2. Equipped with RS485 communication function, it can be connected to control devices with serial communication function in point-to-point or bus mode, greatly improving the distance and depth of signal transmission that has not yet been processed, making it convenient to achieve ultra long distance automatic control.

3. Humanized design, easy to operate.

4. The plug-in packaging structure makes installation simpler and more convenient.

5. Multiple signal outputs can be selected to meet the on-site terminal reception conditions.

6. The overcurrent components are made of corrosion-resistant materials, which have high chemical corrosion resistance characteristics.

7. Diversified installation forms, integrated and split installation are suitable for various complex working conditions.


Pipeline split impeller flowmeter, Jiangsu flowmeter manufacturer, domestic flowmeter brand
Pipeline split impeller flowmeter, Jiangsu flowmeter manufacturer, domestic flowmeter brand
Pipeline split impeller flowmeter, Jiangsu flowmeter manufacturer, domestic flowmeter brand
Pipeline split impeller flowmeter, Jiangsu flowmeter manufacturer, domestic flowmeter brand
Pipeline split impeller flowmeter, Jiangsu flowmeter manufacturer, domestic flowmeter brand
Pipeline split impeller flowmeter, Jiangsu flowmeter manufacturer, domestic flowmeter brand
Pipeline split impeller flowmeter, Jiangsu flowmeter manufacturer, domestic flowmeter brand
Pipeline split impeller flowmeter, Jiangsu flowmeter manufacturer, domestic flowmeter brand
Pipeline split impeller flowmeter, Jiangsu flowmeter manufacturer, domestic flowmeter brand
Pipeline split impeller flowmeter, Jiangsu flowmeter manufacturer, domestic flowmeter brand



Knowledge extension:


What are the structural differences between natural gas flow meters and other flow meters?


The density of gas is much smaller than that of liquid, so gas turbine flow meters have some differences in structure compared to liquid turbine flow meters. The density of gas is greatly affected by changes in temperature and pressure. Therefore, when measuring gas volume flow, gas turbine flow meters with temperature and pressure compensation functions are often used to achieve accurate measurement of gas media. When measuring the volume flow, this turbine flowmeter must track and detect the temperature and pressure of the gas medium, and convert the volume flow of gas under different working conditions into the volume flow under Standard state (P=101.325Kpa T=273.15K).


The temperature and pressure compensated gas turbine flowmeter can use the principle of electromagnetic induction to convert the turbine speed into a pulse signal proportional to the fluid volume flow rate. The signal is input into the arithmetic unit after amplification, filtering and shaping, and is processed together with the temperature and pressure signal. The arithmetic unit calculates according to the gas Equation of state, and the results can be displayed locally or transmitted remotely in various signal forms. If the turbine flowmeter adopts various single-chip microcomputer technologies and micro power consumption technologies as the arithmetic unit, in addition to temperature and pressure compensation, it can also have various functions such as alarm self-diagnosis signal remote transmission, achieving strong functionality and computationessenceHigh precision, compact structure, strong anti-interference ability, wide measurement range, and good repeatability. The gas turbine flowmeter can be applied to the measurement of single-phase gas, standard volume total, and is an ideal instrument for gas measurement in industries such as petrochemical, power metallurgy, and urban gas pipeline networks.




Pipeline split impeller flowmeter, Jiangsu flowmeter manufacturer, domestic flowmeter brand

Trading Area

Global

Quotation

Name
Company
Phone
Email Address
Requirements
Quotation
Guangdong, China
Chat
Manufacturer
Messages