Ultra high precision temperature control ± 0.1 ℃ ± 0.2 ℃ ± 0.5 ℃ precision chiller dedicated to injection molding machines
Ultra high precision temperature control ± 0.1 ℃ ± 0.2 ℃ ± 0.5 ℃ precision chiller dedicated to injection molding machines
Ultra high precision temperature control ± 0.1 ℃ ± 0.2 ℃ ± 0.5 ℃ precision chiller dedicated to injection molding machines
Ultra high precision temperature control ± 0.1 ℃ ± 0.2 ℃ ± 0.5 ℃ precision chiller dedicated to injection molding machines
Ultra high precision temperature control ± 0.1 ℃ ± 0.2 ℃ ± 0.5 ℃ precision chiller dedicated to injection molding machines
Ultra high precision temperature control ± 0.1 ℃ ± 0.2 ℃ ± 0.5 ℃ precision chiller dedicated to injection molding machines
Ultra high precision temperature control ± 0.1 ℃ ± 0.2 ℃ ± 0.5 ℃ precision chiller dedicated to injection molding machines

Ultra high precision temperature control ± 0.1 ℃ ± 0.2 ℃ ± 0.5 ℃ precision chiller dedicated to injection molding machines

$4,355.40/Stand
Place of Origin
China
Shipping
Air Freight, Ocean Freight, Land Freight

Product Description

Overview

brand
BD
model
BD6666
specifications
Processing customization
yes
Compressor brand
Gulun/Sanyo
control mode
DDC controller
Condensation and heat dissipation method
Water cooled/air cooled
Outlet water temperature
5-30 ℃ ± 0.1 ℃
size
Starting from 1100 * 1000 * 1100cm
purpose
High precision temperature control system
power
15KW
Refrigeration capacity range
2KW-200KW
voltage
380V
Compressor form
Fully enclosed vortex
water pump
Flow rate: 15m ³/ H
Refrigerant
R410A/R22
Insulated water tank
304 stainless steel insulated water tank

Product Details

Ultra high precision temperature control ± 0.1 ℃ ± 0.2 ℃ ± 0.5 ℃ precision chiller dedicated to injection molding machines
Ultra high precision temperature control ± 0.1 ℃ ± 0.2 ℃ ± 0.5 ℃ precision chiller dedicated to injection molding machines
Ultra high precision temperature control ± 0.1 ℃ ± 0.2 ℃ ± 0.5 ℃ precision chiller dedicated to injection molding machines
Ultra high precision temperature control ± 0.1 ℃ ± 0.2 ℃ ± 0.5 ℃ precision chiller dedicated to injection molding machines
Ultra high precision temperature control ± 0.1 ℃ ± 0.2 ℃ ± 0.5 ℃ precision chiller dedicated to injection molding machines

1、 Company Introduction
The industrial chillers produced by Shenzhen Bond Refrigeration are technology oriented, forming a source of quality control based on procurement, production, and quality. The materials used in the industrial chillers produced by the company are all brand new products from internationally renowned brands, achieving quality and value.
The product features are as follows:
1. The industrial chillers produced by our company basically cover the entire line of products used by customers, ranging from 1 to several hundred pieces can be produced
2. The temperature control accuracy of the chiller can achieve ± 0.1 ℃ water outlet temperature control. 3. PID automatic control program is used to achieve intelligent temperature control and one click start. 4. The core refrigeration components of the compressor are internationally renowned brand compressors, which operate stably and have a long service life. 5 All electrical components are made of internationally renowned brand Schneider electrical components


2、 The selection process of the chiller is as follows:
Generally, customers only know their required cold water temperature and required chilled water flow rate. According to national standards, the calculation method is as follows:
Q=CM △ T
Among them, Q is the cooling capacity we need, and the cooling capacity calculated by this formula is in KJ/h, which needs to be converted into KW
C is the specific heat capacity of the medium, which is a constant. Taking water as an example, the specific heat capacity of water is 4.2KJ/(KG. ℃)
M is the mass flow rate of the refrigerant carrier
△ T is the temperature difference between the ice water we need. For example, if we need the ice water temperature to be 7 ℃, 7 ℃ before entering the machine for use, and 12 ℃ when exiting the equipment, then △ T=12-7=5 ℃. Generally, the heat exchange temperature difference for equipment is around 5 ℃.
For example, a certain device requires an ice water temperature of 7 ℃ and a flow rate of 10m ³/ h. The refrigerant is water
So we use the formula: Q=CM △ T
Among them: C=4.2KJ/(KG. ℃)
M=10 * 1000=10000kg/h
△ T=5 ℃
Q=4.2 * 10000 * 5=210000 KJ/H converted to KW is 210000/3600=58KW
Choosing a 20 horsepower high-precision chiller from our company Bond Refrigeration can meet the cooling capacity requirements


3、 The specifications of commonly used precision chillers are as follows
Model number, cooling capacity (KW), standard water supply temperature (℃), chilled water flow rate (m ³/ h) Water pump head (m) Compressor power (KW)
BD-F-03 3 7



7 ℃~20 ℃ ± 0.1 ℃ 1.3 19~50 2.35
BD-F-05 5 14 2.5 19-50 3.75
BD-F-10 10 27 4.8 19-50 7.5
BD-F-12 12 32 5.6 19-50 8.82
BD-F-15 15 40 7 19-50 11.25
BD-F-20 20 60 10.56 19-50 14.7
BD-F-24 24 70 12.32 19-50 18
BD-F-30 30 81 14.2 19-50 22
BD-F-40 40 110 19.36 19-50 30
Note: The above refrigeration capacity and compressor power refer to data under national standard operating conditions