Analyzer oxygen content probe high-precision oxygen content analyzer detection probe flue ZO series Shanghai Automation Instrument Factory
Analyzer oxygen content probe high-precision oxygen content analyzer detection probe flue ZO series Shanghai Automation Instrument Factory
Analyzer oxygen content probe high-precision oxygen content analyzer detection probe flue ZO series Shanghai Automation Instrument Factory
Analyzer oxygen content probe high-precision oxygen content analyzer detection probe flue ZO series Shanghai Automation Instrument Factory
Analyzer oxygen content probe high-precision oxygen content analyzer detection probe flue ZO series Shanghai Automation Instrument Factory
Analyzer oxygen content probe high-precision oxygen content analyzer detection probe flue ZO series Shanghai Automation Instrument Factory

Analyzer oxygen content probe high-precision oxygen content analyzer detection probe flue ZO series Shanghai Automation Instrument Factory

$1,379.21
Place of Origin
Global
Shipping
Ocean Freight, Land Freight, Air Freight

Product Description

Overview

brand
Shanghai Automation Instrument Factory
resolving power
zero point zero one
weight
3kg
working temperature
-10 ℃~+50 ℃
type
Oxygen analysis
Processing customization
yes
Display method
Large screen blue background with white text LCD display
size
HxL=300mm x 400mm x 200mm
Imported or not
no
Applicable scope
0-25% O2
Testing items
N2, inert gas, mixed gas, etc
producing area
Shanghai
quantity
ninety-nine

Product Details

Analyzer oxygen content probe high-precision oxygen content analyzer detection probe flue ZO series Shanghai Automation Instrument Factory

1、 Overview:

The intelligent oxygen content analyzer belongs to the national high-tech product and adopts a split installation. A set of instruments consists of two parts, the primary instrument zirconia probe (ISG) and the secondary instrument oxygen transmitter. The connecting wire between the two is generally provided by the user. Specific specifications can be found in the product manual.

2、 Main technical parameters:

Technical parameters

measuring range 0-25% O2
Basic error≤ ± 1% F.S
response time10S reaches 95%
output signal4-20mADC or 0-5V
resolving powerzero point zero one
Zero drift≤ ± 1% F.S/7d
Span Drift ≤ ± 1% F.S/7d
Repeatability error≤ 1%
Working power supplyAC 85V-265V ± 10%, 50/60Hz, power consumption ≤ 20VA
work environment-10 ℃~+50 ℃
Sample gas pressure0.05MPa ≤ Sample gas pressure ≤ 0.5MPa
Alarm contact capacityAC 125V 0.3A, DC 110V 0.3A, DC 30V 1A
Average sensor life>24 months (under normal usage conditions)
External dimensionsHxL=300mm x 400mm x 200mm
Measurement mediumN2, inert gas, mixed gas, etc
Instrument weight3kg

 

3、 Probe length:

Insertion depth L=0.4m, 0.6m, 0.8m, 1m, 1.2m. When selecting the probe, pay attention to the temperature of the flue gas. At<700 ℃ and 700 ℃, we provide a standard zirconia probe. If the temperature of the flue gas is ≥ 700 ℃, we will provide a small high-temperature zirconia probe. If the flue gas contains corrosive gases, we will specially treat the zirconia probe to achieve corrosion resistance.

4、 Selection instructions:

(1) Zirconia probe length

(2) Converter specifications

(3) Temperature of flue gas (whether it contains corrosiveness)


Analyzer oxygen content probe high-precision oxygen content analyzer detection probe flue ZO series Shanghai Automation Instrument Factory

Trading Area

Global

Quotation

Name
Company
Phone
Email Address
Requirements
Quotation
Jiangsu, China
Chat
ManufacturerTradersDistributor
Messages