Maintenance of membrane stack of Clarison Ultrapure water EDI module direct drinking post deionization filtration two-stage reverse osmosis equipment
Maintenance of membrane stack of Clarison Ultrapure water EDI module direct drinking post deionization filtration two-stage reverse osmosis equipment
Maintenance of membrane stack of Clarison Ultrapure water EDI module direct drinking post deionization filtration two-stage reverse osmosis equipment
Maintenance of membrane stack of Clarison Ultrapure water EDI module direct drinking post deionization filtration two-stage reverse osmosis equipment
Maintenance of membrane stack of Clarison Ultrapure water EDI module direct drinking post deionization filtration two-stage reverse osmosis equipment
Maintenance of membrane stack of Clarison Ultrapure water EDI module direct drinking post deionization filtration two-stage reverse osmosis equipment

Maintenance of membrane stack of Clarison Ultrapure water EDI module direct drinking post deionization filtration two-stage reverse osmosis equipment

$987.22/Stand
Place of Origin
China
Shipping
Air Freight, Ocean Freight, Land Freight

Product Description

Overview

brand
Clasen
voltage
220-380
model
KLX500 (0.5T)/KLX1000 (1T)/KLX2000 (2T)/KLX3000 (3T)/KLX4000 (4T)/EDI maintenance
flow
0.3-0.7/0.8-1.2/1.5-2.2/2.5-3.2/3-4.5/4-5.2
Water yield
500-5000
Imported or not
no
working temperature
15-35 ℃ (optimal 25 ℃)
Operation mode
Fully automatic
operational principle
Ion exchange
classification
Pure water machine
Water production method
Continuous and uninterrupted water production
effluent
15 megaohms to 18.25 megaohms
Working current (A, DC)
1-6
Recovery rate
90-95
Water production resistivity m Ω • cm
15-18.25
Fresh water/production water interface (external screw)
DN32
Concentrated water inlet/outlet interface (external screw)
DN20
Silicon and boron removal rate (%)
≥ 99

Product Details

Maintenance of membrane stack of Clarison Ultrapure water EDI module direct drinking post deionization filtration two-stage reverse osmosis equipment
Maintenance of membrane stack of Clarison Ultrapure water EDI module direct drinking post deionization filtration two-stage reverse osmosis equipment
Maintenance of membrane stack of Clarison Ultrapure water EDI module direct drinking post deionization filtration two-stage reverse osmosis equipment
Maintenance of membrane stack of Clarison Ultrapure water EDI module direct drinking post deionization filtration two-stage reverse osmosis equipment
Maintenance of membrane stack of Clarison Ultrapure water EDI module direct drinking post deionization filtration two-stage reverse osmosis equipment
Maintenance of membrane stack of Clarison Ultrapure water EDI module direct drinking post deionization filtration two-stage reverse osmosis equipment
Maintenance of membrane stack of Clarison Ultrapure water EDI module direct drinking post deionization filtration two-stage reverse osmosis equipment
Maintenance of membrane stack of Clarison Ultrapure water EDI module direct drinking post deionization filtration two-stage reverse osmosis equipment
Maintenance of membrane stack of Clarison Ultrapure water EDI module direct drinking post deionization filtration two-stage reverse osmosis equipment
Maintenance of membrane stack of Clarison Ultrapure water EDI module direct drinking post deionization filtration two-stage reverse osmosis equipment
Maintenance of membrane stack of Clarison Ultrapure water EDI module direct drinking post deionization filtration two-stage reverse osmosis equipment
Maintenance of membrane stack of Clarison Ultrapure water EDI module direct drinking post deionization filtration two-stage reverse osmosis equipment
Maintenance of membrane stack of Clarison Ultrapure water EDI module direct drinking post deionization filtration two-stage reverse osmosis equipment
Maintenance of membrane stack of Clarison Ultrapure water EDI module direct drinking post deionization filtration two-stage reverse osmosis equipment
Maintenance of membrane stack of Clarison Ultrapure water EDI module direct drinking post deionization filtration two-stage reverse osmosis equipment
Maintenance of membrane stack of Clarison Ultrapure water EDI module direct drinking post deionization filtration two-stage reverse osmosis equipment
Maintenance of membrane stack of Clarison Ultrapure water EDI module direct drinking post deionization filtration two-stage reverse osmosis equipment
Maintenance of membrane stack of Clarison Ultrapure water EDI module direct drinking post deionization filtration two-stage reverse osmosis equipment
Maintenance of membrane stack of Clarison Ultrapure water EDI module direct drinking post deionization filtration two-stage reverse osmosis equipment
Maintenance of membrane stack of Clarison Ultrapure water EDI module direct drinking post deionization filtration two-stage reverse osmosis equipment
Maintenance of membrane stack of Clarison Ultrapure water EDI module direct drinking post deionization filtration two-stage reverse osmosis equipment
Maintenance of membrane stack of Clarison Ultrapure water EDI module direct drinking post deionization filtration two-stage reverse osmosis equipment

Trading Area

Global

Quotation

Name
Company
Phone
Email Address
Requirements
Quotation
Messages