Yuzhong 136 Vertical Concealed Fan Coil Unit Fan Drainage Pipe Kerite Air Conditioning
Yuzhong 136 Vertical Concealed Fan Coil Unit Fan Drainage Pipe Kerite Air Conditioning
Yuzhong 136 Vertical Concealed Fan Coil Unit Fan Drainage Pipe Kerite Air Conditioning
Yuzhong 136 Vertical Concealed Fan Coil Unit Fan Drainage Pipe Kerite Air Conditioning
Yuzhong 136 Vertical Concealed Fan Coil Unit Fan Drainage Pipe Kerite Air Conditioning
Yuzhong 136 Vertical Concealed Fan Coil Unit Fan Drainage Pipe Kerite Air Conditioning
Yuzhong 136 Vertical Concealed Fan Coil Unit Fan Drainage Pipe Kerite Air Conditioning
Yuzhong 136 Vertical Concealed Fan Coil Unit Fan Drainage Pipe Kerite Air Conditioning
Yuzhong 136 Vertical Concealed Fan Coil Unit Fan Drainage Pipe Kerite Air Conditioning

Yuzhong 136 Vertical Concealed Fan Coil Unit Fan Drainage Pipe Kerite Air Conditioning

$33.39 - 37.75/Stand
Place of Origin
Dezhou, Shandong, China
Shipping
Ocean Freight, Land Freight

Product Description

Overview

Order number
KRTJT-003
Processing customization
type
Article number
KRTJT-003
type
Horizontal concealed fan coil unit
model
FP
brand
Coret
current
2 (A)
voltage
380 (V)
power
120 (w)
Air volume
180-2380
Applicable fan
Double inlet multi blade forward tilting centrifugal fan
Rated cooling capacity
1430-12600
Rated heating capacity
2160-18900
Is it a cross-border source of goods
no
Product specifications
FP-51, FP-102, FP-136, FP-238

Product Details

Company Advantages
Factory direct sales, quality assurance, timely delivery, and thoughtful after-sales service
Product advantages: 7 core technologies
Beautiful design, ultra-thin integration, energy-saving, ultra-low noise, convenient use, compact structure, and durability
The main control parameters for horizontal concealed fan coil units include rated air volume, outlet static pressure, input power, rated cooling capacity, rated heating capacity, noise, water resistance, etc. For the fan coil unit of the dual pipe water system, only one set of coils is configured, which can be used for both winter and summer heating and cooling. For the fan coil unit of the four pipe water system, a combination model of heating and cooling coils should be configured.
Product Details
1. High quality galvanized sheet
Exquisite and atmospheric appearance, advanced technology, beautiful appearance, easy to carry and install
2. Water receiving tray
One time stamping forming water tray, overall inclined design, no water leakage, surface heat invasion electric paint treatment, corrosion resistance
3. Motor
Low noise capacitor motor, imported rolling bearings, reliable operation
4. Volute
Metal volute, Pittsburgh style teeth, high air volume, not easy to rust
(ABS volute, made of brand new material, ultra quiet)
5. Surface cooler
Made of high-quality seamless copper tubes, threaded into the shape with fins, mechanically expanded, and automatically protected by nitrogen gas for welding, with high heat transfer efficiency
6. Collecting head
Made of brass forging, the water flow is evenly distributed, which can achieve ideal overall heat transfer effect
Application site
Large shopping malls, office buildings, hospitals, schools, hotels, factories, etc
Ordering instructions
1. When selecting fan coil units, please specify the product specifications, model, and direction of the inlet and outlet water pipes (facing the front air outlet to distinguish the left and right water pipe directions. When the water pipe is in the left hand direction, it is called the left type, and vice versa, it is called the right type)
2. When selecting horizontal fan coil units that require a return air box, please indicate the return air position of the return air box
3. Please indicate the static pressure at the outlet of the coil, standard 12Pa, and high static pressure is divided into 30Pa and 50Pa. If there are no special requirements, supply according to the standard static pressure type.
4. If it is necessary to extend the water tray, please indicate. If there are no special requirements, standard water trays will be used for supply.
Keruite Air Conditioning Group Co., Ltd. is located in Luquantun Third Industrial Park, Dezhou City, Shandong Province. It is a backbone enterprise that produces various types of fire ventilation equipment such as 3c fans, 3c air valves, fan coils, air conditioning units, ducts, silencers, and central air conditioning end products. It is a modern high-tech enterprise that integrates design, development, manufacturing, sales, installation, and technical services, The company has passed the ISO9001 quality system certification and CCCF mandatory certification, and has a complete and scientific quality management system.
The company was founded in 1997 and has gone through more than ten years of ups and downs, creating its position in the civil wind turbine industry! The company adheres to the quality policy of "paying attention to customer needs, seeking continuous improvement, pursuing management, and providing satisfactory products". With a new management concept, product quality, and comprehensive after-sales service, the company stands out in the fierce competition.
The company currently covers an area of over 80000 square meters, with a construction area of 67000 square meters. It has assets of 50 million yuan and an annual output value of over 80 million yuan. It currently has more than 150 employees, including 30 technical personnel. The production facilities are complete, the process flow is complete, and there is a fan testing laboratory with complete testing methods. There are more than 100 sets of large-scale equipment of various types, such as digital controlled rotary presses, CNC plasma, CNC drilling tower machines, laser plasma, fully automatic air duct production lines, fully automatic copper pipe straightening machines, seamless welding machines, shearing machines, bending machines, forging machines, milling machines, lathes, planers, punches, and other equipment.
The Draught Fan coil unit has undergone design optimization, resulting in a significant improvement in coil performance. The main control parameters selected for the fire exhaust fan are working temperature, air volume, total pressure, efficiency, noise, motor power, speed, and shaft power. The coil unit is divided into two types: the standard type and the standard type. The standard type fan coil unit can meet the various parameters required by the national standard, and the performance parameters of the type fan coil unit are better than the national standard requirements by more than 20%.
Characteristics of fan coil unit:
1. Safe and reliable, with long service life
Each coil heat exchanger is subjected to pressure leakage detection, and the inlet and outlet pipes (collecting heads) are made of forged brass structure, which is reliable and durable. The condensate tray is sprayed with plastic and does not rust. All materials are fire-resistant, and the motor adopts ultra-low noise rolling bearings, which do not require user refueling and maintenance. The service life can reach 35000 hours, and the slender shaft of the motor is specially treated without rust
The fan coil unit should be installed in an open or concealed manner according to the specific situation and decoration requirements of the room, and the installation position and form should be determined. Vertical units are generally placed under the exterior wall windowsill; The horizontal unit is suspended from the upper part of the room; The wall mounted unit is hung above the wall; The column type unit is reliably placed on the ground or inside the partition wall; The cassette unit is embedded in the ceiling.
The surface mounted unit should be placed indoors without the need for decoration, but a unit with a coordinated appearance color and room tone should be selected; Concealed units should be equipped with supply and return air outlets that are coordinated with building decoration, and air outlet filters should be installed at the return air outlet. Removable or openable maintenance openings should also be left during building decoration to facilitate disassembly and maintenance of the fan and motor of the unit, as well as cleaning of the air heat exchanger.
Horizontal installation units are often hidden on the ceiling, and there are two types of air supply methods: upper side air supply box and downward air supply from the ceiling. If the side supply method is adopted, low static pressure fan coil units can be selected, and the unit outlet is directly connected to a double layer louver air outlet; If ceiling downward air supply is used, high static pressure fan coil units should be selected. The unit air supply outlet can be connected to a section of air duct, which is connected to several diffusers for downward air supply. There are two ways to return air for horizontal concealed units: installing louvers or other forms of return air outlets and air outlet filters on the ceiling, connecting them to the return air box of the unit with air ducts, without air ducts. Indoor air enters the ceiling and is then sucked in by the unit placed on the ceiling.
In addition, when selecting fan coil units, attention should be paid to the room's requirements for noise control.

Yuzhong 136 Vertical Concealed Fan Coil Unit Fan Drainage Pipe Kerite Air Conditioning
Yuzhong 136 Vertical Concealed Fan Coil Unit Fan Drainage Pipe Kerite Air Conditioning
Yuzhong 136 Vertical Concealed Fan Coil Unit Fan Drainage Pipe Kerite Air Conditioning

Yuzhong 136 Vertical Concealed Fan Coil Unit Fan Drainage Pipe Kerite Air Conditioning
Yuzhong 136 Vertical Concealed Fan Coil Unit Fan Drainage Pipe Kerite Air Conditioning

Trading Area

Global

Quotation

Name
Company
Phone
Email Address
Requirements
Quotation
Shandong, China
Chat
Manufacturer
Messages