DRK122 Derek transmittance haze meter Plastic film transmittance tester
DRK122 Derek transmittance haze meter Plastic film transmittance tester
DRK122 Derek transmittance haze meter Plastic film transmittance tester
DRK122 Derek transmittance haze meter Plastic film transmittance tester
DRK122 Derek transmittance haze meter Plastic film transmittance tester
DRK122 Derek transmittance haze meter Plastic film transmittance tester
DRK122 Derek transmittance haze meter Plastic film transmittance tester
DRK122 Derek transmittance haze meter Plastic film transmittance tester

DRK122 Derek transmittance haze meter Plastic film transmittance tester

$7,259.00
Place of Origin
China
Shipping
Air Freight, Ocean Freight, Land Freight

Product Description

Overview

brand
Derrick
encapsulation
purpose
Plastic film transmittance tester
lift
load
Processing customization
yes
Display method
Digital display
Quality assurance services
One year
Measurement range
response time
relative humidity
Stretch Space
Environmental requirements for use
Support collection technology
material
size
Number of channels
structural style
Applicable medium
Imported or not
no
working voltage
two hundred and twenty
LCD display update
Repeatability error
Input signal voltage
Measurable sample status
Number of boxes packed
Graduation value
Indication error
UV wavelength
Measurement object
Measurement repeatability
Filter specifications
Continuous working hours
Temperature compensation range
Sampling flow range
Lattice value
focal length
noise
colour
serial number
Sampling rate
Smoothness
Crosshair
Effective diameter
Pupillary distance
Dielectric strength
Scale circle diameter
Closest working distance
Coupling type
New and old degree
Net weight
21KG
Counter base
Overall dimensions
740mm × 270mm × 300mm
environment condition
10-50 ° C
Sample size
50mm × 50mm
Tank size
fifty × fifty × 10MM

Product Details

DRK122 Derek transmittance haze meter Plastic film transmittance tester
DRK122 Derek transmittance haze meter Plastic film transmittance tester

The DRK122 Derek transmittance haze meter for plastic film transmittance is developed and manufactured in accordance with technical standards such as GB 2410-80, ASTM D1003-61 (1997), and JIS k7105-81. It adopts parallel lighting, hemispherical scattering, and integrating sphere photoelectric reception. It adopts a microcomputer automatic operation system and data processing system, without knob operation, and is convenient to use. It also has a standard print output pull port, which automatically displays the average value of multiple measurements of transmittance/haze, The transmittance results are displayed to 0.1%, and the haze is displayed to 0.01%. There is no zero drift and strong confidence. The specific structure of the open sample window is almost not limited by the sample size, and the measurement speed is fast. Due to the use of the adjustment product, the instrument is not affected by ambient light, and there is no need to use a dark room. This ensures the safety of large sample operators, and the microcomputer based electronic circuit has high accuracy and is equipped with a standardized data printing and output interface, Programmable printers can be supplied as a supporting device. Equipped with thin film magnetic fixtures and liquid sample cups, it brings convenience to users. Attached with a haze gauge, it is convenient to check the instrument's action function at any time.
DRK122 Derek Transmittance Haze Meter Plastic Film Transmittance Tester is suitable for measuring the transmittance, transmission haze, reflection haze, and reflectance of all transparent and semi transparent parallel plane samples (plastic sheets, sheets, plastic films, and flat glass), as well as for measuring the turbidity of liquid samples (water, beverages, pharmaceuticals, coloring liquids, oils). It has * * * applications in scientific research and industrial and agricultural production, It is also suitable for measuring the transmittance of optical glass and detecting the freshness of photosensitive films,


DRK122 Derek transmittance haze meter Plastic film transmittance tester
DRK122 Derek transmittance haze meter Plastic film transmittance tester

Intermediate control of polarization degree of artificial polarizer, measurement of visibility of aviation glass, Car glass and gas mask glass, evaluation of comprehensive optical quality of packaging plastic Thin-film optics, inspection of light transmission rate of agricultural plastic film, inspection of light transmission characteristics of building and decoration glass, assessment of diffusion quality of optical projection screen, measurement of diffusion ability of film screen and projection television screen, inspection of quality of light box screen in Guangzhou, inspection of quality of engineering drawing paper, The light transmittance/haze tester can also be indirectly applied to the evaluation of Frosted glass detergent quality, the evaluation of the light efficiency of plastic polishing materials, the determination of Vritz flocs, the evaluation of the scratch ability of plastic glass masks, and the control and detection of the diffuse characteristics of diffuse coatings. The transmittance/haze tester is used to measure the turbidity of liquid samples, including: textile factory, thermal power plant, steel plant, bulb factory, semiconductor factory, Paper mill, Synthetic fiber factory, industrial water detection, waterworks, soda plants, breweries, sugar, pharmaceutical and clinical applications in the determination of trace solids and substance concentration in mother liquor of crystals, the determination of bacterial concentration in epidemic prevention stations, clinical blood tests, and the determination of * * * clarity*** Inspection of sewage treatment quality, control of seawater desalination quality, determination of turbidity of coloring solution in chemical industry, determination of turbidity of oil and solvent, quality inspection of edible water and beverages in factories, monosodium glutamate factories, and seasoning factories.


DRK122 Derek transmittance haze meter Plastic film transmittance tester
DRK122 Derek transmittance haze meter Plastic film transmittance tester

DRK122 Derek transmittance haze meter plastic film transmittance tester, product parameters:
Sample window size entering the window Φ 25mm exit window Φ 21mm;
Light source C (DC12V 50W halogen tungsten lamp+color temperature film)
Receiver silicon photocell+visual function correction plate (compliant with V( λ) Standard value);
Precision transmittance 0.1% haze 0.01%;
Measurement range: transmittance 0-100.0%; Haze 0-30.00%
Sample size 50mm × 50mm
Tank size 50 × fifty × 10MM
Instrument size 740mm × 270mm × 300mm
Net weight of instrument 21KG
Power supply 220V 50HZ
Environmental conditions 10-50 ° C
Product configuration:
One host, one manual, one power cord, and one halogen tungsten lamp for backup.
Note: Due to technological progress, the information is subject to change without prior notice. The actual product in the future shall prevail.


DRK122 Derek transmittance haze meter Plastic film transmittance tester
DRK122 Derek transmittance haze meter Plastic film transmittance tester
DRK122 Derek transmittance haze meter Plastic film transmittance tester
DRK122 Derek transmittance haze meter Plastic film transmittance tester
DRK122 Derek transmittance haze meter Plastic film transmittance tester
DRK122 Derek transmittance haze meter Plastic film transmittance tester
DRK122 Derek transmittance haze meter Plastic film transmittance tester
DRK122 Derek transmittance haze meter Plastic film transmittance tester
DRK122 Derek transmittance haze meter Plastic film transmittance tester

Trading Area

Global

Quotation

Name
Company
Phone
Email Address
Requirements
Quotation
Shandong, China
Chat
ManufacturerTradersDistributor
Messages