Hazardous gases in the urban comprehensive pipeline corridor of the GX-3R four-in-one gas detector developed by Nippon Institute of Technology
Hazardous gases in the urban comprehensive pipeline corridor of the GX-3R four-in-one gas detector developed by Nippon Institute of Technology
Hazardous gases in the urban comprehensive pipeline corridor of the GX-3R four-in-one gas detector developed by Nippon Institute of Technology
Hazardous gases in the urban comprehensive pipeline corridor of the GX-3R four-in-one gas detector developed by Nippon Institute of Technology
Hazardous gases in the urban comprehensive pipeline corridor of the GX-3R four-in-one gas detector developed by Nippon Institute of Technology
Hazardous gases in the urban comprehensive pipeline corridor of the GX-3R four-in-one gas detector developed by Nippon Institute of Technology

Hazardous gases in the urban comprehensive pipeline corridor of the GX-3R four-in-one gas detector developed by Nippon Institute of Technology

$653.31
Place of Origin
China
Shipping
Air Freight, Ocean Freight, Land Freight

Product Description

Overview

brand
RIKEN KEIKI
source
Lithium battery charging
resolving power
%LEL
Operation mode
Processing customization
no
Indication error
purpose
Marine oxygen and explosion measuring instrument
Number of boxes packed
Graduation value
UV power
Applicable scope
Imported or not
Measurement object
CH4 O2 H2S CO
ambient temperature
Analysis time
Measurement repeatability
Filter specifications
Continuous working hours
Temperature compensation range
Sampling flow range
Overall dimensions
material
packing
model
GX-3R
Number of channels
Thickness detection
LCD display update
Repeatability error
Input signal voltage
Measurable sample status
size
58 * 65 * 26
weight
100G
measuring range
0-100% LEL
Display method
Digital display type sound and light vibration alarm
Applicable to
Ship users. Daily protection for steel mills and others
Protection level
IP68
Charging duration
3 hours
Place of shipment
Jinan, Shandong
certificate
Explosion proof, MED marine certificate
replace
GX-2009

Product Details

Hazardous gases in the urban comprehensive pipeline corridor of the GX-3R four-in-one gas detector developed by Nippon Institute of Technology
Hazardous gases in the urban comprehensive pipeline corridor of the GX-3R four-in-one gas detector developed by Nippon Institute of Technology
Hazardous gases in the urban comprehensive pipeline corridor of the GX-3R four-in-one gas detector developed by Nippon Institute of Technology

What are the hazardous gases in the urban comprehensive pipe gallery



Urban underground pipe gallery is a municipal public facility that implements unified planning, design, construction and maintenance, and is built underground in the city for laying municipal public pipelines. Before the construction of urban underground comprehensive pipe gallery, workers actually work in a confined environment or in a confined space during the construction process. The Occupational hazard protection of employers working in confined space is particularly important.


In the "Technical Specification for Urban Comprehensive Pipe Corridor Engineering", it is clearly stated that environmental monitoring of comprehensive pipe corridors is one of the very important norms. The purpose of gas monitoring is to avoid causing harm to personnel inside the pipeline gallery.

Different pipe corridors may face different monitoring issues, such as:

picture
Water supply pipelines, regeneration water pipelines, and rainwater pipeline corridors must monitor O2;

The sewage pipeline gallery must monitor O2, H2S, and CH4;

The natural gas pipeline corridor must monitor O2 and CH4;

The thermal pipeline corridor must monitor O2;

Power cables and communication cable galleries must monitor O2;


Hazardous gases in the urban comprehensive pipeline corridor of the GX-3R four-in-one gas detector developed by Nippon Institute of Technology

For personnel safety: Use portable gas detectors to keep inspectors away from dangerous gases.

▼ Portable

For maintenance and repair work projects, operators can carry portable gas detectors [GW-3, GX-3R/Pro], which can detect toxic gases in a timely manner for safe operation.


Hazardous gases in the urban comprehensive pipeline corridor of the GX-3R four-in-one gas detector developed by Nippon Institute of Technology

Using personal multi gas detectors, area monitors, and real-time monitoring technology is a good choice



The Institute of Science and Technology has been focusing on gas detection technology for many years. Targeted at sub gas detection scenarios such as damp, semi enclosed, and long project distances in underground pipeline corridors, it has developed suitable sensors, effectively solving many problems such as equipment being prone to moisture and corrosion, poor ventilation causing accuracy decline, and data reliability reduction caused by long communication distances. It collects real-time concentrations of oxygen, combustible gases, and toxic and harmful gases in underground spaces, Ensure the gas environment safety inside the pipe gallery.


Hazardous gases in the urban comprehensive pipeline corridor of the GX-3R four-in-one gas detector developed by Nippon Institute of Technology
Hazardous gases in the urban comprehensive pipeline corridor of the GX-3R four-in-one gas detector developed by Nippon Institute of Technology

Trading Area

Global

Quotation

Name
Company
Phone
Email Address
Requirements
Quotation
Shandong, China
Chat
ManufacturerTradersDistributor
Messages