VOLKE electronic flow sensor flow controller flow sensor fluid sensor
VOLKE electronic flow sensor flow controller flow sensor fluid sensor
VOLKE electronic flow sensor flow controller flow sensor fluid sensor
VOLKE electronic flow sensor flow controller flow sensor fluid sensor
VOLKE electronic flow sensor flow controller flow sensor fluid sensor
VOLKE electronic flow sensor flow controller flow sensor fluid sensor

VOLKE electronic flow sensor flow controller flow sensor fluid sensor

$61.70 - 72.59/Stand
Customization

Logo (Min. order 500 Stand)

Packaging (Min. order 500 Stand)

Graphic (Min. order 500 Stand)

Module Number
FES
Place of Origin
Shenzhen, Guangdong, China
Shipping
Ocean Freight, Air Freight

Product Description

Overview

Product characteristics
Long lifespan
Imported or not
No
Producing area
Shenzhen
Brand
VOLKE
Model
FES economic electronic flow switch
3C rated voltage range
36V and below
Working voltage
DC24V
Overload current
2A
Lifetime times
Long lifespan
Protection level
IP67
Product Certification
CE
Processing customization
Yes

Product Details

Supplied by the manufacturer, supporting customizationWelcome to consult!

FES economic electronic flow switch

VOLKE electronic flow sensor flow controller flow sensor fluid sensor

Product Introduction:

Real time monitoring of liquid flow in the pipeline, providing on off output, and using 6 LEDs to display real-time fluid flow rate status can achieve the following monitoring functions: medium flow, reducing/including flow rate; The medium exists/does not exist; Medium flow/stillness; Monitor the flow rate of fluid in the pipeline, monitor flow interruption, or prevent pump idling It is applied in industries such as petrochemical, power, metalurgy, steel mills, papermaking, food processing, water treatment, battery factories, etc

VOLKE electronic flow sensor flow controller flow sensor fluid sensor

Product parameters:

Measurement range: water: 0.03-3m/s;

Oil: 0.03-3m/s;

Gas: 2-20 m/s

Withstand voltage: 1.6 M P a

Connection method: Thread G 1/2 ^ ^, G 1/4 ^ ^ ^, other

Switching time: O N: typical ≥ 4 s (1-13 s);

O F F: Typical ≥ 4 s (1-15 s)

Temperature change reaction time: ≤ 12 seconds

Working voltage: D C 2 4 V

Power consumption: 2 W

Output: Relay, N P N/P N P output

Contact capacity: 2 A/220 VAC, 3 A/30VDC

Insulation impedance: 100 M Ω at 100V D C

Number of control points: 1 pair

Contact capacity: 2A/220 VAC, 3A/30VDC

Insulation impedance: 100 M Ω at 100VD C

Probe material: 304 stainless steel

Shell material: PP

Working temperature: -10 ℃ -60 ℃

Environmental conditions: -20~85 ℃, ≤ 85% R H

Protection level: I P 6 7

Product features:

1. Economic, suitable for large scale use on equipment, reducing costs

2. Replace the handle type flow switch with sensitive action and long service life

3. It can effectively prevent angle

4. Fully waterproof shell design

5. Suitable for a wide range of pipe diameters and can be adjusted accordingly

6. The indicator light directly displays changes in flow rate

Conventional flow switches or flow signals are often used for buffle or piston type, releasing on liquid flow power to push the buffle or piston to move, resulting in high water resistance, large flow loss, poor accuracy, and inability to monitor small flow rates The sealing part is sealed with metal corroded pipes, which has poor pressure resistance and are prone to metal fatigue and cracking

Product packaging and accessories:

VOLKE electronic flow sensor flow controller flow sensor fluid sensor

Knowledge extension:

How should the flow controller be installed?

How should the flow controller be installed? 1. Selection of target films

The flow switches produced by our company are required with detachable targets of variable specifications at the factory, except for the ones required by customers to be required with plates Different targets can be selected according to the actual installation status If there is no suitable length of target, it can be trimmed with slightly longer targets Water flow controller Manufacturer of oilfield water injection flow controller

It should be noted that the installation of the target film should not be too long, as it may touch the pipe wall if it is too long; The installation of the target should not be too short, as it will affect the sensitivity of the switch, and in separate cases, it will cause the switch to not operate

How should the flow controller be installed? 2. Installation of water flow switch

Please remember that the flow switch must be installed on a straight pipeline, with at least 5 times the diameter of the pipeline on both sides

When timing the water flow switch, the target should be persistent to the flow direction of the fluid, and the arrow direction on the flow switch shell should be consistent with the flow direction of the fluid in the pipeline Water flow switches can be installed in horizontal pipelines or vertical pipelines with upward liquid flow direction, but cannot be installed in pipelines with downward liquid flow

Third, when reviewing the flow switch into the pipeline tee, in order to prevent damage to the switch, it is not allowed to hold the shell for installation, and a hexagonal writing must be used to hold the six corners of the valve body for installation

Fourth, the flow switch must not be subject to water hammer If a quick closing valve is installed below the flow switch, a suitable throttle must be used to prevent water hammer

VOLKE electronic flow sensor flow controller flow sensor fluid sensor

Trading Area

Global

Quotation

Name
Company
Phone
Email Address
Requirements
Quotation
Guangdong, China
Chat
Manufacturer
Messages