Industrial Flow Switch Oil Flow Switch Flow Regulating Switch Company
Industrial Flow Switch Oil Flow Switch Flow Regulating Switch Company
Industrial Flow Switch Oil Flow Switch Flow Regulating Switch Company
Industrial Flow Switch Oil Flow Switch Flow Regulating Switch Company
Industrial Flow Switch Oil Flow Switch Flow Regulating Switch Company
Industrial Flow Switch Oil Flow Switch Flow Regulating Switch Company

Industrial Flow Switch Oil Flow Switch Flow Regulating Switch Company

$72.59 - 108.89/Stand
Customization

Logo (Min. order 500 Stand)

Packaging (Min. order 500 Stand)

Graphic (Min. order 500 Stand)

Module Number
FCT
Place of Origin
Shenzhen, Guangdong, China
Shipping
Ocean Freight, Air Freight

Product Description

Overview

Product characteristics
Waterproof
Imported or not
No
Producing area
Shenzhen
Brand
VOLKE
Model
FCT heat exchange flow switch
3C rated voltage range
36V and below
Working voltage
DC24, AC/DC220V
Overload current
2A
Lifetime times
Long lifespan
Protection level
IP67
Product Certification
Product Qualification Certificate
Processing customization
Yes

Product Details

Industrial Flow Switch Oil Flow Switch Flow Regulating Switch Company

Characteristics ★ Full water proof shell design, water proof adjustment knob. ★ It can effectively prevent the angle of wind materials in the medium. ★ Full water proof shell design, water proof adjustment knob ★ Suitable for a wide range of pipe diameters and can be adjusted arbitrarily ★ Optional high voltage type, with a stand voltage of up to 600Bar; Optional anti corrosion type The indicator light directly displays the flow change

Industrial Flow Switch Oil Flow Switch Flow Regulating Switch CompanyWorking principleFCT type water cut off alarm flow switch switch signal output

 

 

Main technical parameters

 

  

 

Wiring diagram

The FCT type flow switch can easily set the flow alarm node, unscrew the protective thread, and adjust the bottom knob with a threaded knifeSet the flow alarm point. For flow switches with output forms of PNP, NPN, and relays, the meaning of their LED indicators is as follows: - Red light on, flow rate lower than set (transient not conducting/relay not acting) - Yellow w light on, Flow rate equal to or higher than set (transient conduction/relay action) - The flow rate of the yellow and green lights exceeds the set level (green lights 1, 2, 3, or 4 lights up together with the yellow light)

 

Industrial Flow Switch Oil Flow Switch Flow Regulating Switch Company

Structure Description

Industrial Flow Switch Oil Flow Switch Flow Regulating Switch Company

 

Installation instructions

 

Industrial Flow Switch Oil Flow Switch Flow Regulating Switch Company

 

 

Product factory packaging and accessories

Industrial Flow Switch Oil Flow Switch Flow Regulating Switch Company

Knowledge extension:

A brief introduction to flow switches

The flow switch is mainly installed online or plug-in to monitor the water flow in the water system of water, gas, oil, and other medium pipelines When the water flow rate is higher or lower than a certain setting, an alarm signal is triggered and transmitted to the unit After observing this signal, the system can make corresponding instructions Avoid or reduce the ^ ^ dry burn ^ ^ of the host

Set the upper or lower limit of the flow switch When the flow reaches the limit value, the flow switch will send a signal or alarm, and the system will run or stop Systems that typically require flow will use flow switches

The working principle of the flow switch:

The working principle of the flow switch is when there is water flowing through the flow switch and the water flow rate

When the water flow is ≥ 1.0L/min, the magnetic core in the water flow switch is displayed by the water flow The magnetic core display drives the magnetic source to generate a magnetron function, causing the water flow switch to output an ^ ^ open ^ ^ signal This signal is input to the device control system, which implements control functions When the water flow rate is less than the initial flow rate, the flow switch outputs a ^ ^ close ^ ^ signal The control system products the candidate control effect as described above In other words, when the water flow switch in the pipeline is greater than 1L/min, the magnetic core shifts and drives under the action of water flow The source generates magnetic control function, causing the sensor to output a ^ ^ 1 ^ ^ ^ switch signal, which is input to the device control system to receive the purpose of water flow control after power amplification When the flow rate is less than 1L/min, the magnetic core drives the magnetic source back under the rust of the reset spring, causing the sensor to output a ^ ^ 0 ^ ^ switch signal to stop the system operation

Advantages of flow switches:

The low flow (volume) effect of the water flow switch

2. The flow switch has a simple structure and a small contact surface

3. The flow switch is also suitable for low content debris flow

When the flow switch is blocked by special fabrics, it can be removed online

Industrial Flow Switch Oil Flow Switch Flow Regulating Switch Company

Trading Area

Global

Quotation

Name
Company
Phone
Email Address
Requirements
Quotation
Guangdong, China
Chat
Manufacturer
Messages