Fujian Sanming anti floating underground fire water tank with an effective volume of 108 cubic meters
Fujian Sanming anti floating underground fire water tank with an effective volume of 108 cubic meters
Fujian Sanming anti floating underground fire water tank with an effective volume of 108 cubic meters
Fujian Sanming anti floating underground fire water tank with an effective volume of 108 cubic meters
Fujian Sanming anti floating underground fire water tank with an effective volume of 108 cubic meters
Fujian Sanming anti floating underground fire water tank with an effective volume of 108 cubic meters

Fujian Sanming anti floating underground fire water tank with an effective volume of 108 cubic meters

$14,518.00
Place of Origin
China
Shipping
Air Freight, Ocean Freight, Land Freight

Product Description

Overview

model
YX
producing area
Yancheng, Jiangsu
material quality
Stainless steel, galvanized sheet, composite sheet
Water tank connection method
Bolted connection
Liquid level control method
Remote control float
anticorrosion
asphalt
Material of pressure strip
EPDM
Protection level of control cabinet
IP55
purpose
Water supply equipment
Qualification
complete
power
15KW
Processing customization
yes
Export or not
no
Cooling method
Self cooling
brand
Yuxuan

Product Details

Fujian Sanming anti floating underground fire water tank with an effective volume of 108 cubic meters

Schematic diagram of internal details of buried fire water tank
1 Φ Assembled with 10 * 30 hot-dip galvanized screws and environmentally friendly and water resistant * * * adhesive strips
2. The outlet pipe of the fire protection system adopts a dual outlet.
3. The water tank module is made of hot-dip galvanized steel plate 3mm and 0.4mm304/2B food grade stainless steel plate, which are pressed and laminated through equipment to ensure a close fit, thus meeting the requirements of steel plate material strength and corrosion resistance of stainless steel.
4. The interior of the water tank should be equipped with a fire protection * * dry motor long shaft pump (dry motor deep well pump) or a dry motor vertical pipeline pump fire pump
5. Equipped with intelligent control cabinets for automatic and manual control, with remote operation functions, complete protection functions, and reliable operation.
6. After the water tank is assembled and formed, install the tie bars and top columns, and select the tie bars Φ 40 hot-dip galvanized pull, less than 1 meter vertically and horizontally installed. Selection of top pillar Φ 40 hot-dip galvanized pipes are evenly sealed with 4 pipes per square meter.
7. The internal part of the pump is reinforced with 14 # I-beam, which can achieve good pressure bearing effect.


Fujian Sanming anti floating underground fire water tank with an effective volume of 108 cubic meters
Fujian Sanming anti floating underground fire water tank with an effective volume of 108 cubic meters

Use of buried fire pool equipment:
1. Choose a well ventilated, dust-free, and non humid area with an ambient humidity of -10 ℃ -40 ℃. Rain and lightning protection facilities should be installed outdoors.
2. For the convenience of equipment installation, a 70cm space should be left around the equipment, a 1.5m space should be left at the manhole, and drainage ditches should be set up on the surrounding ground.
3. After selecting the site, it is necessary to prepare the foundation, use concrete pouring or masonry to build the tank support seat. After the base is fully cured, lift the tank body and place it firmly, then install the accessories and connect the power supply.
4. Before the test run, the water supply valve should be closed first, and the condition of each sealing valve should be checked. No leakage is allowed. After driving, attention should be paid to the direction of the pump. When the pressure gauge pointer reaches the upper limit, the pump automatically stops. Open the water supply valve to provide normal water supply. If a timed water supply is required, turn the selector switch to the manual position.
5. The pump unit of this equipment should be inspected regularly, and lubricating oil should be added regularly. If water leakage is found in the centrifugal pump and check valve, the flange screws should be tightened in a timely manner or the asbestos root should be replaced. Check that the anchor bolts of the pump should not be loose to prevent damage to the machine.
6. The automatic control system of electrical appliances should be waterproof, dustproof, and regularly check the insulation of the circuit, whether the connecting bolts are loose, and whether the wires are intact. The outer part of the pressure gauge should be wrapped with transparent material to prevent damage.
7. If any paint peeling is found on the tank body, it should be painted in a timely manner to extend its service life.