Guangdong Guangzhou Underground Fire Water Tank Anti floating Box Pump Integrated Pump House
Guangdong Guangzhou Underground Fire Water Tank Anti floating Box Pump Integrated Pump House
Guangdong Guangzhou Underground Fire Water Tank Anti floating Box Pump Integrated Pump House
Guangdong Guangzhou Underground Fire Water Tank Anti floating Box Pump Integrated Pump House
Guangdong Guangzhou Underground Fire Water Tank Anti floating Box Pump Integrated Pump House
Guangdong Guangzhou Underground Fire Water Tank Anti floating Box Pump Integrated Pump House

Guangdong Guangzhou Underground Fire Water Tank Anti floating Box Pump Integrated Pump House

$14,518.00
Place of Origin
China
Shipping
Air Freight, Ocean Freight, Land Freight

Product Description

Overview

producing area
Yancheng, Jiangsu
Saleable land
nationwide
Water tank connection method
Bolted connection
Liquid level control method
Remote control float
Protection level of control cabinet
IP55
Material of pressure strip
EPDM
anticorrosion
asphalt
purpose
Fire water supply
material quality
Galvanized sheet, composite sheet
Cooling method
Self cooling
Export or not
no
Processing customization
yes
power
45KW
Qualification
complete
brand
Yuxuan

Product Details

Guangdong Guangzhou Underground Fire Water Tank Anti floating Box Pump Integrated Pump House

Use of buried fire pool equipment:
1. Choose a well ventilated, dust-free, and non humid area with an ambient humidity of -10 ℃ -40 ℃. Rain and lightning protection facilities should be installed outdoors.
2. For the convenience of equipment installation, a 70cm space should be left around the equipment, a 1.5m space should be left at the manhole, and drainage ditches should be set up on the surrounding ground.
3. After selecting the site, it is necessary to prepare the foundation, use concrete pouring or masonry to build the tank support seat. After the base is fully cured, lift the tank body and place it firmly, then install the accessories and connect the power supply.
4. Before the test run, the water supply valve should be closed first, and the condition of each sealing valve should be checked. No leakage is allowed. After driving, attention should be paid to the direction of the pump. When the pressure gauge pointer reaches the upper limit, the pump automatically stops. Open the water supply valve to provide normal water supply. If a timed water supply is required, turn the selector switch to the manual position.
5. The pump unit of this equipment should be inspected regularly, and lubricating oil should be added regularly. If water leakage is found in the centrifugal pump and check valve, the flange screws should be tightened in a timely manner or the asbestos root should be replaced. Check that the anchor bolts of the pump should not be loose to prevent damage to the machine.
6. The automatic control system of electrical appliances should be waterproof, dustproof, and regularly check the insulation of the circuit, whether the connecting bolts are loose, and whether the wires are intact. The outer part of the pressure gauge should be wrapped with transparent material to prevent damage.
7. If any paint peeling is found on the tank body, it should be painted in a timely manner to extend its service life.


Guangdong Guangzhou Underground Fire Water Tank Anti floating Box Pump Integrated Pump House

The advantages of underground fire pool water supply equipment are as follows:
1. Underground fire water tank saves space: the water pump and pump room are placed in the water tank and fixed on the module of the integrated pump station. Usually, only 0.5~1.5m of water tank volume is occupied.
2. The underground fire water tank is easy to move and disassemble, and has a long service life. Due to the use of prefabricated stainless steel water tanks, the previous welding method has been changed. It is assembled with screws, which has strong applicability, convenient installation, and does not require * * equipment.
3. The underground fire water tank is easy to evacuate: due to the use of a new type of submersible fire pump, it can be directly submerged in the water without the need for specialized air discharge. As long as the water tank level is within the specified level, it can directly enter the fire water supply state.
4. Buried fire water tank to prevent freezing and cracking: The fire pump is buried deep in the water tank and will not be burned out due to freezing in winter.
5. Buried fire water tank with low noise: equipped with a submerged motor and water pump, greatly reducing operating noise.
6. Reliability of buried fire water tanks: Water immersed motors will not burn out or corrode motor bearings due to rain or environmental temperature.
7. The upgrade of the underground fire pool is simple: there is an interface left to support remote transmission and automatic cleaning.