Power plant dedicated pressure transmitter Power plant pressure sensor 4-20mA hart protocol
Power plant dedicated pressure transmitter Power plant pressure sensor 4-20mA hart protocol
Power plant dedicated pressure transmitter Power plant pressure sensor 4-20mA hart protocol
Power plant dedicated pressure transmitter Power plant pressure sensor 4-20mA hart protocol
Power plant dedicated pressure transmitter Power plant pressure sensor 4-20mA hart protocol
Power plant dedicated pressure transmitter Power plant pressure sensor 4-20mA hart protocol

Power plant dedicated pressure transmitter Power plant pressure sensor 4-20mA hart protocol

$41.38 - 47.18/Stand
Place of Origin
China
Shipping
Air Freight, Ocean Freight, Land Freight

Product Description

Overview

brand
Jichuang
model
JC-2000-FB
series
packing
Part status
type
Power plant pressure transmitter
Input Range
output
quarantine
response time
accuracy
Voltage - Power Supply
Installation type
Termination Style
working temperature
Certification Authority
Minimum packaging quantity
Processing customization
yes
measuring range
-0.1MPa~60MPa
Measurement medium
Gas, liquid
Accuracy level
0.2 level, 0.5 level
output signal
4-20mA, Hart protocol
Explosion proof level
BT6
Protection level
IP65
supply voltage
24V
Interface size
M20 * 1.5 customizable
quantity
nine thousand nine hundred and ninety-nine

Product Details

Power plant dedicated pressure transmitter Power plant pressure sensor 4-20mA hart protocol

Parameter specifications

Technical indicators
Measurement mediumLiquid, gas
Measurement range-0.1-60MPa (customizable within the range)
Accuracy0.2 level, 0.5 level
Signal output4-20mA, 4-20mA stacked with HART, RS485
Supply voltage24VDC (12VDC-36VDC)
Medium temperature-40-+100
Storage temperature-40-+100 (without LCD meter) -40-+70 (with LCD meter)
Operating temperature of the entire machine-40-+85 (without LCD meter) -30-+60 (with LCD meter)
Environmental temperature-0-100 relative humidity
Power impactLess than 0.0059/V of output range
Load impactNo load impact, unless there is a change in power supply voltage
Zero point migrationWhen the zero shift is negative, the lower range limit must be greater than or equal to - URL;
When zero shift is positive, the range must be less than or equal to+URL. The calibration range must be greater than or equal to the minimum range
Zero and SpanAdjustments can be made using the local range and zero button, or remotely using a HART handheld device
Damping time constantAdjustable time constant in increments of 0.1 seconds, from minimum to 16.0 seconds
Explosion proof levelIntrinsically safe type: Exia II CT6 Flameproof type: Exd II BT5
Protection levelIP65


Power plant dedicated pressure transmitter Power plant pressure sensor 4-20mA hart protocolPower plant dedicated pressure transmitter Power plant pressure sensor 4-20mA hart protocol

Power plant dedicated pressure transmitter Power plant pressure sensor 4-20mA hart protocolPower plant dedicated pressure transmitter Power plant pressure sensor 4-20mA hart protocol

Power plant dedicated pressure transmitter Power plant pressure sensor 4-20mA hart protocol

Power plant dedicated pressure transmitter Power plant pressure sensor 4-20mA hart protocol

Power plant dedicated pressure transmitter Power plant pressure sensor 4-20mA hart protocol



Trading Area

Global

Quotation

Name
Company
Phone
Email Address
Requirements