Anhui Fuyang buried fire water tank assembly type composite water tank adopts anti floating method
Anhui Fuyang buried fire water tank assembly type composite water tank adopts anti floating method
Anhui Fuyang buried fire water tank assembly type composite water tank adopts anti floating method
Anhui Fuyang buried fire water tank assembly type composite water tank adopts anti floating method
Anhui Fuyang buried fire water tank assembly type composite water tank adopts anti floating method
Anhui Fuyang buried fire water tank assembly type composite water tank adopts anti floating method

Anhui Fuyang buried fire water tank assembly type composite water tank adopts anti floating method

$14,518.00
Place of Origin
China
Shipping
Air Freight, Ocean Freight, Land Freight

Product Description

Overview

producing area
Yancheng, Jiangsu
power
75KW
material quality
Stainless steel, galvanized sheet, composite sheet
Saleable land
nationwide
Qualification
complete
Water tank connection method
Bolted connection
Liquid level control method
Remote control float
anticorrosion
asphalt
Protection level of control cabinet
IP55
temperature
0-30 degrees Celsius
Material of pressure strip
EPDM
Export or not
no
Processing customization
yes
purpose
Fire water supply
brand
Yuxuan

Product Details

Anhui Fuyang buried fire water tank assembly type composite water tank adopts anti floating method

BDF water tank features:
1. Corrosion resistance: The inner layer of the composite plate is made of SUS304 food grade stainless steel, which has high corrosion resistance. The outer layer is made of hot-dip galvanized steel plate, and after installation, the finished product is coated with anti-corrosion paint, which has multiple corrosion resistance.
2. Strength: Galvanized steel plate has good internal and external pressure.
3. Ideal mechanical structure: From a mechanical perspective, the protruding part of the double water tank adopts a sphere.
4. No leakage: * * structural design, no welding combination on site. High strength, good sealing performance, preventing secondary pollution of water quality.
5. Easy construction: Users can propose any combination of length, width, and height of the water tank according to their design needs (standard plates are 1m * 1m, 1m * 0.5m). There are no special requirements on the installation site, especially suitable for buried and oversized water tanks, commonly seen in fire water tanks, and can provide insulation (polyurethane foam insulation, rock wool and rubber plastic insulation) services.
6. Requirements for stainless steel water tank concrete foundation: The height difference of the concrete foundation plane is less than 5mm, the spacing between each beam is 100cm, and the height is greater than 50cm.


Anhui Fuyang buried fire water tank assembly type composite water tank adopts anti floating method

BDF water tank assembly method
1. Firstly, assemble and assemble the molded plates, and use bolts and sealing rings to seal and connect the plates according to the size of the water tank × wide × High bolt tightening;
2. After assembling several large panels, the bottom plate assembly is carried out. Firstly, the size of the water tank bottom plate is aligned, and then the bottom plate is laid on the water tank foundation for sealing connection. After the bottom plate is connected, fire oil inspection or visual inspection of the sealing area is carried out;
3. After the bottom plate is connected, the wall panel and bottom plate are connected. The bolt connection involves first placing one side of the code on the bottom plate of the water tank. After the four wall codes are installed, adjust the connection by pressing the edges. The relative angle of the compound ruler generally does not exceed 2mm, and it is required to be in a straight line. The four corners require the bottom to be perpendicular to the wall connection;
4. After the bottom of the water tank and the wall are sealed and connected with bolts and sealing rings, the top and wall are connected, and the edges are required to be basically on a horizontal line. The water tank manhole is connected to the * * position according to customer requirements, usually located near the floating ball of the inlet hole;
5. After the connection and sealing of the water tank body are completed, then open inlet, outlet, overflow, sewage, fire holes, and install the rear escalator near the manhole;
6. The internal tie bars of the box are made of stainless steel plates and folded into right angle angle steel and channel steel through a folding machine. The tie bars are connected in a layer from the bottom up 50cm, with a vertical and horizontal spacing of 1m between each layer × 1m, * distance between the two layers * 50cm for the first layer, height and spacing, and so on. The wall is connected to the wall, the wall is connected to the bottom plate, and the wall is connected to the top plate with angle steel;
7. After the completion of various tasks, if water testing conditions are available on site, conduct water injection and pressure testing on the water tank, and check the sealing areas around the water tank for any leakage or water seepage.


Anhui Fuyang buried fire water tank assembly type composite water tank adopts anti floating method