COD detector with multiple parameters of ammonia nitrogen, total phosphorus, total nitrogen, and heavy metals
COD detector with multiple parameters of ammonia nitrogen, total phosphorus, total nitrogen, and heavy metals
COD detector with multiple parameters of ammonia nitrogen, total phosphorus, total nitrogen, and heavy metals
COD detector with multiple parameters of ammonia nitrogen, total phosphorus, total nitrogen, and heavy metals
COD detector with multiple parameters of ammonia nitrogen, total phosphorus, total nitrogen, and heavy metals

COD detector with multiple parameters of ammonia nitrogen, total phosphorus, total nitrogen, and heavy metals

$1,671.86 - 5,698.28/Stand
Lead time
Quantity (Stand) 1-1011-100101-1000
Lead time (day)3715
Module Number
GL-900
Place of Origin
Heze, Shandong, China
Shipping
Ocean Freight, Land Freight, Air Freight

Product Description

Overview

Repeatability
1%
Optical stability
≤ ± 0.001 Abs/20 minutes (100000 hour lifespan)
Operating system
Equipped with Glos water quality intelligent detection system
Screen display
8 inches 1024 × 768 IPS level high definition capacitive touch screen
Instrument power supply
DC 12V, 5A
Work environment
5-40 ℃, ≤ 85% non condensing
Instrument size
408mm × 208mm × 126mm
Instrument weight
5.2kg

Product Details

Product Overview

The GL-900 multi-parameter water quality test conforms to the principles recognized by the environmental protection industry, equipped with imported light sources and sensors, and advanced optical structure design It also supports two color methods: tube color and dish color The tube color options a 360 ° rotation color method, Which can improve the stability of the measurement data by 10 times and effectively solve the testing error caused by scratches on the tube wall The test data can be automatically synchronized with the Green Cloud IoT platform and permanently stored in the cloud It can be viewed and recorded remotely in real-time on mobile and computer devices, And relevant information such as sampling locations and personnel can be edited The 8-inch IPS level high definition touch screen equipped with the Glos water quality detection system integrates various applications such as water quality analysis, photometric measurement, self built curves, data batch printing, batch export, guided detection, and batch detection

Application area

It can be widely used in water quality testing in scientific research institutions, water engineering, water environment testing, petrochemical industry, metalurgy and steel, biopharmaceutical, food and day industry, wood text printing and dynamics, electronic machinery, aquaculture, photovoltaic, leather, papermaking, and other fields

Functional characteristics

Equipped with 360 ° rotation colorimetric technology, the stability is improved by 10 times

Imported solid state cold light source with a lifespan of 100000 hours and stable performance

Equipped with independently developed Glos water quality intelligent detection system, making detection simpler and more intelligent

Advanced optical system enables all beams of light to be focused and imaged to the sensor, improving the accuracy of detection results

Support the determination of variable water quality pollutants and can expand the measurement project

Guided operation, easy to complete water quality measurement according to screen guidance prompts

Paired with a dual colorimetric system, supporting both tubes and dish colorimetry

Users can learn self built curve functions and provide customized calibration of coefficient curves and sample curves

The program can be updated and measurement data can be exported through the USB interface

8 inches 1024 × 768 resolution IPS level high definition capacitive touch screen

Touch operated Stereo feedback provides a more compatible operating experience between the fingers

Build in thermal printer, supporting automatic printing and batch printing

ABS material, high strength, resistance, and high performance resistance shell

EQUIPPED with a multifunctional intelligent digestion instrument, the water sample project can be digested with just one click

It is required with imported Biohit Pipeline, which reduces the error of water sampling and is simpler and more stable

General parameters

Testing items

COD

Measurement standards

HJ/T399-2007

Range

0-15000mg/L (segmented)

Lower detection limit

5mg/L

Anti chlorine interference

2000mg/L

Digestion temperature

165 ℃, 20min

Indication error

COD ≤ 50mg/L, ± 4mg/L; COD > 50mg/L, error ≤ ± 3%

Measurement time

25 minutes/batch

Testing items

Ammonia nitrogen

Measurement standards

HJ535-2009

Range

0-50mg/L (segmented)

Lower detection limit

0.05mg/L

Digestion temperature

No need for digestion

Indication error

± 0.1mg/L or ≤ ± 3%

Measurement time

5 minutes/batch

Testing items

Total phorus

Measurement standards

GB11893-89

Range

0-16mg/L (segmented)

Lower detection limit

0.02mg/L

Digestion temperature

150 ℃, 15min

Indication error

± 0.004mg/L or ≤ ± 3%

Measurement time

20 minutes/batch

Testing items

Total nitrogen

Measurement standards

Alkaline supersulfate digestion spectrophotometry

Range

0-250mg/L (segmented)

Lower detection limit

0.05mg/L

Digestion temperature

120 ℃, 30min

Indication error

± 0.4mg/L or ≤ ± 3%

Measurement time

35 minutes/batch

Performance parameter

Repeatability

1%

Optical stability

≤ ± 0.001 Abs/20 minutes (100000 hour lifespan)

Color comparison method

Dual colorimeter cell, supporting both 360 ° rotary tube colorimeter and dish colorimeter

Printer

Build in micro thermal printer

Operating system

Equipped with Glos water quality intelligent detection system

IoT functionality

Unlimited permanent storage of detection data on Green Cloud Server, which can be viewed in real-time on mobile phones and computers

Screen display

8 inches 1024 × 768 IPS level high definition capacitive touch screen

Device Functions

Water quality analysis, photometric measurement, data management, self build coefficient curve, self build standard sample curve, PC online, USB upgrade, etc

Instrument power supply

DC 12V, 5A

Work environment

5-40 ℃, ≤ 85% non condensing

Instrument size

408mm × 208mm × 126mm

Instrument weight

About 5.2kg

All parameter indicators

Testing items

Range (expandable)

Lower detection limit

Testing standards

COD

0-15000mg/L

5mg/L

HJ/T 399-2007

Ammonia nitrogen

0-50mg/L

0.05mg/L

HJ535-2009

Total phorus

0-16mg/L

0.02mg/L

GB/T 11893-1989

Total nitrogen

0-250mg/L

0.05mg/L

Alkaline supersulfate digestion spectrophotometry

*Total nitrogen

0-150mg/L

0.05mg/L

(Applicable only to 800UV) HJ 636-2012

Chroma

0-500PCU

5PCU

GB/T 11903-1989

Turbidity

0-100NTU

1 NTU

GB/T 13200-1991

Suspended solids

0-500mg/L

1mg/L

GB/T 11901-1989

Copper

0-1mg/L

0.04mg/L

Dicyclohexanone oxalyl dihydrone photometric method

Nickel

0-1mg/L

0.002mg/L

PAN spectrophotometry

Iron

0-5mg/L

0.02mg/L

HJ/T345-2007

Zinc

0-3mg/L

0.05mg/L

Xylenol orange method

Hexavalent chromium

0-1mg/L

0.01mg/L

GB7467-87

Total chromium

0-1mg/L

0.01mg/L

GB7466-87

Cobalt

0-2mg/L

0.02mg/L

HJ550-2015

Manganese

0-16mg/L

16mg/L

HJ/T344-2007

Permanganate index

0.5-5mg/L

0.25mg/L

GB11892-89

Sulfide

0-1mg/L

0.01mg/L

GB/T16489-96

Volatile phenol

0-2mg/L

0.01mg/L

HJ503-2009

Cyanide

0-0.5mg/L

0.01mg/L

HJ484-2009

Fluoride

0-1.6mg/L

0.02mg/L

HJ 488-2009

Chlorides

0-15mg/L

0.1mg/L

Mercury (II) thiocyanate spectrophotometry

Residual chlorine

0-3mg/L

0.02mg/L

HJ 586-2010

Total residual chlorine

0-3mg/L

0.02mg/L

HJ 586-2010

Chlorine dioxide

0-5mg/L

0.05mg/L

HJ 586-2010

Nitrite

0-0.2mg/L

0.003mg/L

GB7493-87

Nitrate nitrogen

0-20mg/L

0.1mg/L

Chromotropic acid spectrophotometry

Photospee

0-1.6mg/L

0.02mg/L

GB/T 11893-1989

Sulfonate

8-200mg/L

2mg/L

HJ/T342-2007

Anionic surfactants

0-2mg/L

0.02mg/L

GB/T7494-87

Formaldehide

0-1mg/L

0.01mg/L

GB/T 18204.2-2014

COD detector with multiple parameters of ammonia nitrogen, total phosphorus, total nitrogen, and heavy metalsCOD detector with multiple parameters of ammonia nitrogen, total phosphorus, total nitrogen, and heavy metalsCOD detector with multiple parameters of ammonia nitrogen, total phosphorus, total nitrogen, and heavy metalsCOD detector with multiple parameters of ammonia nitrogen, total phosphorus, total nitrogen, and heavy metalsCOD detector with multiple parameters of ammonia nitrogen, total phosphorus, total nitrogen, and heavy metalsCOD detector with multiple parameters of ammonia nitrogen, total phosphorus, total nitrogen, and heavy metalsCOD detector with multiple parameters of ammonia nitrogen, total phosphorus, total nitrogen, and heavy metalsCOD detector with multiple parameters of ammonia nitrogen, total phosphorus, total nitrogen, and heavy metalsCOD detector with multiple parameters of ammonia nitrogen, total phosphorus, total nitrogen, and heavy metalsCOD detector with multiple parameters of ammonia nitrogen, total phosphorus, total nitrogen, and heavy metals

Trading Area

Global

Quotation

Name
Company
Phone
Email Address
Requirements
Quotation
Messages