TH30F10025C7 Charging Module National Grid Standardized Power Supply Multiple Protocols 30KW DC200-1000V
TH30F10025C7 Charging Module National Grid Standardized Power Supply Multiple Protocols 30KW DC200-1000V
TH30F10025C7 Charging Module National Grid Standardized Power Supply Multiple Protocols 30KW DC200-1000V
TH30F10025C7 Charging Module National Grid Standardized Power Supply Multiple Protocols 30KW DC200-1000V
TH30F10025C7 Charging Module National Grid Standardized Power Supply Multiple Protocols 30KW DC200-1000V
TH30F10025C7 Charging Module National Grid Standardized Power Supply Multiple Protocols 30KW DC200-1000V
TH30F10025C7 Charging Module National Grid Standardized Power Supply Multiple Protocols 30KW DC200-1000V

TH30F10025C7 Charging Module National Grid Standardized Power Supply Multiple Protocols 30KW DC200-1000V

$578.54 - 631.53
Place of Origin
China
Shipping
Air Freight, Ocean Freight, Land Freight

Product Description

Overview

brand
Dongduo
model
TH30F10025C7
Power module type
Number of voltage output groups
Minimum input voltage
285-475V
Maximum input voltage
output voltage
200-1000VDC
Output current (maximum/full load)
58A
Total output power
30kw
Isolation voltage
conversion efficiency
≥ 95%
Packaging/Specifications
435 * 300 * 84mm
packing
Certification Authority
CE
Minimum packaging quantity
one
quantity
one
encapsulation
carton
Batch number
001
Input method
Three phase+PE
power factor
Full load ≥ 0.99
standby power
<12W

Product Details

1 Product Introduction


TH30F10025C7 is a high efficiency, high power density, super
AC/DC module with a wide constant power range. This product supports 285VAC-475VAC (line voltage) three-phase four wire system (three-phase+PE) input, with a rated output power of 30kW and a constant power range of 250-1000VDC. The charging module communicates with the main monitoring system through the CAN bus to set the charging module parameters, collect the operating parameters of the charging module, and control the working status of the charging module.


1.1 Product Appearance


The overall dimensions of this module (including connectors, excluding handles and front panel protrusions) are: 437.5mm in length, 84mm in height, and 300mm in width.


TH30F10025C7 Charging Module National Grid Standardized Power Supply Multiple Protocols 30KW DC200-1000V
TH30F10025C7 Charging Module National Grid Standardized Power Supply Multiple Protocols 30KW DC200-1000V
TH30F10025C7 Charging Module National Grid Standardized Power Supply Multiple Protocols 30KW DC200-1000V

1.2 Definition of input/output terminals


TH30F10025C7 Charging Module National Grid Standardized Power Supply Multiple Protocols 30KW DC200-1000V
TH30F10025C7 Charging Module National Grid Standardized Power Supply Multiple Protocols 30KW DC200-1000V
TH30F10025C7 Charging Module National Grid Standardized Power Supply Multiple Protocols 30KW DC200-1000V

2.1 Principle Block Diagram


TH30F10025C7 Charging Module National Grid Standardized Power Supply Multiple Protocols 30KW DC200-1000V

2.2 Module Features


Input voltage range (AC): 285-475V
Output voltage regulation range (DC): 50-1000V
Working temperature range: -30~+75 ℃
Peak efficiency: ≥ 96%
High power factor: above 1/3 load ≥ 0.99
Low harmonic content: above half load ≤ 5%
Low standby power consumption:<13W
Output constant power function: output 1000-250VDC constant 30kW
Digital current sharing technology, with parallel unevenness of less than ± 5%
CAN bus communication
Quick insertion and removal installation
Short circuit without damage
Intelligent fan speed control
Supporting parallel voltage and current regulation functions
Equipped with comprehensive protection functions
Input overvoltage and undervoltage protection, input overcurrent protection, and phase loss protection
Output overvoltage protection and current limiting protection
Output anti backflow
Environmental temperature detection and protection
Group current sharing function
Support grouping settings for modules in the system, and module output power lines are required during grouping output
Isolated from each other, each module is only connected to the CAN bus, and each group of modules can
Independently controlling its output voltage and current can achieve grouped current sharing output. Suggested number of modules in each group
≤ 24.


TH30F10025C7 Charging Module National Grid Standardized Power Supply Multiple Protocols 30KW DC200-1000V
TH30F10025C7 Charging Module National Grid Standardized Power Supply Multiple Protocols 30KW DC200-1000V
TH30F10025C7 Charging Module National Grid Standardized Power Supply Multiple Protocols 30KW DC200-1000V
TH30F10025C7 Charging Module National Grid Standardized Power Supply Multiple Protocols 30KW DC200-1000V
TH30F10025C7 Charging Module National Grid Standardized Power Supply Multiple Protocols 30KW DC200-1000V
TH30F10025C7 Charging Module National Grid Standardized Power Supply Multiple Protocols 30KW DC200-1000V

Trading Area

Global

Quotation

Name
Company
Phone
Email Address
Requirements
Quotation
Messages