Overview

brand
Shangyi Third Factory
Thermocouple category
Nickel chromium nickel silicon
Code
WRN
Graduation
K
Measurement range ℃
0-1300
Allowable deviation △ t ℃
± 2.5 ℃ or ± 0.75% | t |
install
Direct installation
interface
Movable flange
producing area
Shanghai
customization
yes
quantity
nine hundred and ninety-nine

Product Details

The WRN-330 assembled thermocouple, as a sensor for measuring temperature, is usually used in conjunction with display instruments, recording instruments, electronic computers, etc. It can directly measure the temperature of liquid, steam, gas media, and solid surface in various production processes within the range of 0-1800 ℃. In addition, it has the advantages of simple assembly, convenient replacement, spring-loaded temperature sensing components, good vibration resistance, large measurement range, high mechanical strength, and good pressure resistance.

Working principle:

The working principle of WRN-330 thermocouple is that two different components of conductors are welded at both ends to form a circuit. The direct temperature measurement end is called the measurement end, and the wiring terminal end is called the reference end. When there is a temperature difference between the measurement end and the reference end, thermal electromotive force will be generated in the circuit. When connected to a display instrument, the instrument will indicate the corresponding temperature value of the thermoelectric electromotive force generated by the thermocouple. The thermoelectric electromotive force of a thermocouple will increase as the temperature at the measuring end increases. The magnitude of the thermoelectric electromotive force is only related to the material of the thermocouple conductor and the temperature difference at both ends, and is not related to the length and diameter of the thermoelectric electrode.

The WRN-330 assembled thermocouple mainly consists of a basic structure consisting of a junction box, protective tube, insulating sleeve, wiring terminal, and thermoelectric electrode, and is equipped with various installation and fixing devices.


Main technical indicators:

Temperature measurement range and allowable error

Thermocouple category

Code

Graduation

Measurement range ℃

Allowable deviation △ t ℃

Nickel chromium nickel silicon

WRN

K

0~1300

± 2.5 ℃ or ± 0.75% | t |

Note "t" represents the measured temperature of the temperature sensing element

Thermal response time

When there is a step change in temperature, the output of the thermocouple changes to 50% of the change, and the time required is called the thermal response time, denoted by T0.5.

Thermocouple nominal pressure

It generally refers to the static external pressure that the protective tube can withstand at room temperature without rupture. In fact, the allowable working pressure is not only related to the material and diameter of the protective tube, but also to its structural form, installation method, insertion depth, and the flow rate and type of the measured medium. It should not be less than 8-10 times the outer diameter of its protective tube (except for special products).

Thermocouple insulation resistance (at room temperature) 

The test voltage for insulation resistance at room temperature is 500V ± 50V DC, and the atmospheric conditions for measuring insulation resistance at room temperature are 15-35 ℃, 45% relative humidity, and 86-106kPa atmospheric pressure.

a. For thermocouples with a length exceeding 1 meter, the product of their insulation resistance at room temperature and their length should not be less than 100

That is, Rr. L ≥ 100 M Ω. M L > 1m

In the formula: Rr - The insulation resistance value of the thermocouple at room temperature M Ω

b. For thermocouples with a length equal to or less than 1 meter, their insulation resistance at room temperature should not be less than 100 M Ω


Upper limit temperature insulation resistance  

The upper limit temperature insulation resistance of thermocouples should not be less than the following:

Upper limit temperature tm ℃

Test temperature t ℃

Resistance value M Ω

100 ≤ tm < 300

T=tm

ten

300 ≤ tm < 500

T=tm

two

500 ≤ tm < 850

T=tm

zero point five

850 ≤ tm < 1000

T=tm

zero point zero eight

1000 ≤ tm < 1300

T=tm

zero point zero two

Tm > 1300

T=1300

zero point zero two


The WRN-330 model represents:

WR

thermocouple

content


Code

Type of thermoelectric electrode

R

Platinum rhodium 30- Platinum rhodium 6

P

Platinum Rhodium 10 Platinum

N

Nickel silicon nickel silicon

M

Nickel chromium silicon nickel silicon

E

Nickel chromium copper nickel

C

Copper nickel

F

Iron copper nickel


Code

Number of output signals

nothing

two

Single branch

Double branch

Code

Fixed device form


one

two

three

four

five

six

seven

Non fixed device type

Fixed thread

Movable flange

Fixed flange

Movable flange angle square type

Fixed threaded conical pipe

Straight pipe joint type

Code

Terminal box form

two

three

four

Splash proof type

Waterproof

Explosion proof type


Code

Protective tube diameter

0

Φ 16mm protective tube

one

Φ 25mm protective tube

two

Φ 16mm high aluminum protective tube

three

Φ 20mm high aluminum protective tube



WRN-330 Assembled Thermocouple Movable Flange Thermocouple from Shangyi Third Factory