Product Description

Overview

brand
Kolut
weight
380KG
source
380V
temperature range
18-30
measuring range
18-30
Processing customization
yes
Sterilization method
high temperature
material quality
Stainless steel
model
KLT-J100
Test chamber volume
1m3 ± 0.1m3
Studio size
eight hundred and fifty × one thousand and eighty × 1100mm
Appearance size
one thousand four hundred and sixty × one thousand two hundred and twenty-five × 1820mm
temperature control
Cycle temperature control
Humidity range
≤ ± 3% RH
humidity control
Refrigeration dehumidification and steam humidification (external)

Product Details

Test steps
1. Simultaneously adjust the temperature and relative humidity of two aerosol cabinets (or chambers) to the required temperature (20 C~25 C) and relative humidity (70%~80%) for the test.
2. Place the test group and control group samples as required.
3. The experimental group shall prepare according to the volume of the aerosol cabinet (or chamber) and the disinfectant product instruction manual (concentration and dosage) and the number of cycles
Prepare the required disinfectant, and calculate the spray time according to the flow of the spray device; Adjust the parameters of the disinfection machine according to the user manual and the number of cycles, and set the startup time. If unstable disinfectants such as oxidizing agents are used to prepare disinfectant, they should be prepared on the same day.


Bacterial aerosol chamber Antibacterial air chamber 1m ³ Metal corrosion aerosol cabinet Kolut

Group *: Disinfectant dosage according to the instructions. Within 1m ³ Spray hard water on the aerosol cabinet and wait for the disinfection time. Immediately use a liquid impact sampler containing 10 mL of neutralizer to sample (the sampling volume is the same as the preset disinfection effect identification test sampling volume), and operate for 10 minutes to draw 0.1mL of test bacterial suspension into the aforementioned neutralizer solution. Conduct live bacterial culture counting.


Bacterial aerosol chamber Antibacterial air chamber 1m ³ Metal corrosion aerosol cabinet Kolut

Group 2; According to the instructions, the amount of disinfectant required is within 1m ³ Spray air disinfectant on the aerosol cabinet. After the disinfection time is reached, immediately use a liquid impact sampler containing 10ml of neutralizer for sampling (the sampling volume is the same as the preset sampling volume for disinfection effect evaluation test). Take 0.1ml of the test bacterial suspension and incubate it in the above neutralization product solution for 10 minutes. Count the live bacterial cultures.